ProForm PFSB73930 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Fitness, Gymnastik & Krafttraining ProForm PFSB73930 herunter. ProForm PFSB73930 User`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
USER’S MANUAL
QUESTIONS?
If you have questions, or if there
are missing parts, we will guar-
antee complete satisfaction
through direct assistance from
our factory.
TO AVOID DELAYS, PLEASE
CALL DIRECT TO OUR TOLL-
FREE CUSTOMER HOT LINE.
The technicians on our customer
hot line will provide immediate
assistance, free of charge.
CUSTOMER HOT LINE:
1-877-897-7493
Mon.–Fri., 8 a.m.–5 p.m. CST
Model No. PFSB73930
Serial No.
The serial number is on a sign
behind the access panel. Write the
serial number in the space above.
CAUTION
Read all precautions and instruc-
tions in this manual before using
this equipment. Save this manual
for future reference.
Visit our website at
www.proform.com
new products, prizes,
fitness tips, and much more!
Access
Panel
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - USER’S MANUAL

USER’S MANUALQUESTIONS?If you have questions, or if thereare missing parts, we will guar-antee complete satisfactionthrough direct assistance fromour

Seite 2 - Table of Contents

10The hydrotherapy spa is designed to seat sevenadults. The spa holds approximately 375 gallons ofwater and offers a heating system (80°F to 104°F), a

Seite 3 - Important Safety Instructions

118. After one minute, the current temperature of thewater will be displayed. Push the temperature upor down button to set the temperature of thewater

Seite 4

12Spa Shell DiagramAOLBDIEIHFMMMJJLLPQLLKKKKKKKKGCCCCCCNLPLA. The filter can be removed for cleaning or replace-ment (see CHECKING AND CLEANING THE FI

Seite 5 - SAVE THESE INSTRUCTIONS

13Using the ControlsAir Control 1 determines the amount of air flowingthrough the hydrotherapy jets labeled 1 in the drawingabove. If the control is t

Seite 6 - Before You Begin

14The Light Button turns the underwater light on andoff.The Temperature Buttons control the temperature set-ting of the water. The temperature setting

Seite 7

15MaintenanceThe hydrotherapy spa is designed to provide years ofenjoyment. Please follow the guidelines below toproperly maintain your spa.MAINTENANC

Seite 8 - Assembly

16WATER CHEMISTRYMaintaining the pH level of the water is very importantto the operation of the spa. To maintain the proper pHlevel and to sanitize th

Seite 9

17ATTACHING AND REMOVING THE ACCESS PANELTurn off the spa power. To remove the indicatedAccess Panel (25), remove the four #10 x 2” MachineScrews (46)

Seite 10 - Using the Hydrotherapy Spa

18DRAINING THE PUMPSAfter the hydrotherapy spa is drained, the jet pumpsshould also be drained if the spa will be stored formore than thirty days or i

Seite 11

191. SYMPTOM: THE SPA WILL NOT OPERATEa. Check to see if the GFCI breaker is tripped orwas not turned on. Reset the GFCI breaker.2. SYMPTOM: THE CIRCU

Seite 12 - Spa Shell Diagram

2PROFORM is a registered trademark of ICON Health & Fitness, Inc.Posting the Warning Sign . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 13 - Using the Controls

209. SYMPTOM: THE WATER LEVEL DROPSa. A clamp or seal inside the pump compartmentmay be loose. Check inside the pump compart-ment for excess water and

Seite 14

21NOTES

Seite 15 - Maintenance

221 1 Console With Overlay2 2 3-wire Power Cord3 1 Filter Cover4 8 Rubber Washer5 1 Filter6 2 Rubber Isolator7 1 Blue Light Cover8 1 Red Light Cover9

Seite 16

2627251829181120122153743443640394142413835464646463394714*99305250505353497834341545451*52232116243221319*2823311364548 233141310*281364548 233123314

Seite 17

Part No. 195331 R0303A Printed in USA © 2003 ICON Health & Fitness, Inc.To order replacement parts, simply call our Customer Service Department to

Seite 18

3WARNING:To reduce the risk of drowning, electric shock, or serious injury, read the fol-lowing important precautions before using the hydrotherapy sp

Seite 19 - Troubleshooting

420.DANGER—Risk of electric shock. Keep allelectrical appliances such as radios, tele-phones, televisions, and lights at least fivefeet away from the

Seite 20

5WARNING: Read all instructions before using the hydrotherapy spa. ICON assumes noresponsibility for personal injury or property damage sustained by o

Seite 21

6Congratulations for selecting the new PROFORM®MAGNA hydrotherapy spa. The innovative MAGNAspa allows you to enjoy all the benefits of hydrothera-py i

Seite 22 - Part List—Model No. PFSB73930

7There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors varydepending on whether you plan to use th

Seite 23

82. Close the valve knob on the drain hose. Thread thecap onto the drain hose.Locate the four gate valves inside the access open-ing (there are two ga

Seite 24 - Limited Warranty

95. Make sure that a qualified electrician has wired thespa to a 240 volt power source. Remove the two warning decals (see page 5) fromthe spa shell.

Kommentare zu diesen Handbüchern